Open-plan office · Target RT60 0.40–0.60 s (Acoustic design references)

Open-plan office RT60 calculator & product comparison. Neutrally.

Shared workspace where speech spill should be controlled (~0.5 s typical). Estimate untreated reverberation time (RT60) with the Sabine equation and compare how many panels, baffles, or clouds each manufacturer requires to reach 0.40–0.60 seconds.

46 products 16 manufacturers ASTM C423 cited
Room parameters
ft
ft
ft

Open-plan office: Shared workspace where speech spill should be controlled (~0.5 s typical). Target 0.40–0.60 s · Acoustic design references.

Baseline: Everyday furniture and a few soft surfaces — an average occupied room. (α ≈ 0.10).

Reverberation · RT60 decay
Treatment needed
Current
1.69 s
Target
0.50 s
Acceptable band 0.40–0.60 s (min 0.60 s)
0 -20 -40 -60 0.0s 0.6s 1.3s 1.9s LEVEL (dB) TIME →
Room volume
20000 ft³
Absorption needed
1383 ft²-sabins
≈ paneling @ NRC 0.90
1173–1537 ft²
min → recommended

Matching products (46) · no manufacturer favored

Independent comparison — not affiliated with or endorsed by the manufacturers listed. Confirm specs against the manufacturer before specifying.

Kinetics Noise Control Wall Panel
HardSide Acoustical Wall Panel Best fit NRC 1.00
Units needed
×35
min ×27
→ 0.50 s custom size · 40 ft²/unit
Units needed
×44
min ×34
→ 0.50 s 35 ft²/unit
Units needed
×44
min ×33
→ 0.49 s custom-made · 40 ft²/unit
USG Ceiling Cloud
Units needed
×49
min ×38
→ 0.50 s 46 × 94 in (representative) · 30 ft²/unit
Decoustics Ceiling Tile
Decoustics Claro NRC 0.90 Unverified
Units needed
×49
min ×37
→ 0.49 s up to 48 × 96 in (custom) · 32 ft²/unit
Units needed
×55
min ×42
→ 0.49 s 48 × 96 in · 32 ft²/unit
Autex Acoustics Wall Panel
Units needed
×55
min ×42
→ 0.50 s 47.25 × 110 in · 36 ft²/unit
Units needed
×58
min ×44
→ 0.50 s 48 × 96 in (representative) · 32 ft²/unit
Autex Acoustics Free-standing Screen
Cascade Hanging Screen NRC 0.65 Unverified
Units needed
×69
min ×53
→ 0.50 s 47 × 94.5 in · 31 ft²/unit
Sound Seal Ceiling Cloud
Poly-Coustix Stratux Cloud NRC 1.30 NRC > 1.0
Units needed
×70
min ×53
→ 0.50 s 47 × 47 in · 15 ft²/unit
Decoustics Wall Panel
Decoustics Quadrillo NRC 1.00 Unverified
Units needed
×70
min ×53
→ 0.50 s custom (up to ~20 ft²/panel) · 20 ft²/unit
Kirei Wall Panel
EchoPanel 12mm NRC 0.55
Units needed
×70
min ×54
→ 0.50 s 47.25 × 110.25 in · 36 ft²/unit
Ecophon (CertainTeed) Ceiling Cloud
Units needed
×91
min ×70
→ 0.50 s 48 × 48 in · 16 ft²/unit
MergeWorks Wall Panel
Units needed
×91
min ×70
→ 0.50 s 36 × 72 in (representative) · 18 ft²/unit
MergeWorks Wall Panel
Units needed
×109
min ×83
→ 0.50 s 47 × 47 in (representative) · 15 ft²/unit
Arktura Wall Panel
SoftScreen Solid NRC 0.40
Units needed
×109
min ×83
→ 0.50 s 48 × 96 in (representative) · 32 ft²/unit
Snowsound Free-standing Screen
Pli NRC 1.00
Units needed
×135
min ×103
→ 0.50 s 23.5 × 63 in · 10 ft²/unit
Turf Design Ceiling Cloud
Fractal Modular Ceiling Cloud NRC 1.15 NRC > 1.0
Units needed
×155
min ×118
→ 0.50 s 36 in module · 8 ft²/unit
Pinta Acoustic Baffle
SONEX One Baffle NRC 1.05 NRC > 1.0
Units needed
×165
min ×126
→ 0.50 s 24 × 48 in · 8 ft²/unit
Units needed
×173
min ×132
→ 0.50 s 48 × 24 in (representative) · 8 ft²/unit
Primacoustic Ceiling Cloud
Units needed
×173
min ×132
→ 0.50 s 24 × 48 in (representative) · 8 ft²/unit
Primacoustic Wall Panel
Units needed
×173
min ×132
→ 0.50 s 24 × 48 in (representative) · 8 ft²/unit
Units needed
×182
min ×139
→ 0.50 s 24 × 48 in (representative) · 8 ft²/unit
Rockfon Ceiling Tile
Rockfon Sonar NRC 0.95
Units needed
×182
min ×139
→ 0.50 s 24 × 48 in · 8 ft²/unit
Snowsound Baffle
Units needed
×183
min ×140
→ 0.50 s 17.3 × 63 in · 8 ft²/unit
MergeWorks Baffle
EchoDeco Baffle NRC 0.90 Unverified
Units needed
×193
min ×147
→ 0.50 s varies by design · 8 ft²/unit
Arktura Ceiling Tile
VaporSoft Cora NRC 0.90
Units needed
×193
min ×147
→ 0.50 s 24 × 48 in · 8 ft²/unit
Units needed
×195
min ×149
→ 0.50 s 23.75 × 47.75 in · 8 ft²/unit
Units needed
×204
min ×156
→ 0.50 s 24 × 48 in (representative) · 8 ft²/unit
MergeWorks Ceiling Tile
Units needed
×209
min ×160
→ 0.50 s 23.75 × 47.5 in (representative) · 8 ft²/unit
Units needed
×210
min ×161
→ 0.50 s 94.5 in fin, 11.8 in deep · 8 ft²/unit
Pinta Acoustic Wall Panel
Units needed
×217
min ×165
→ 0.50 s 24 × 48 in · 8 ft²/unit
Pinta Acoustic Ceiling Tile
Units needed
×220
min ×168
→ 0.50 s 23.75 × 47.75 in · 8 ft²/unit
Snowsound Wall Panel
Flat NRC 1.00
Units needed
×222
min ×169
→ 0.50 s 30 × 30 in (bounding box; irregular) · 6 ft²/unit
Units needed
×231
min ×176
→ 0.50 s 48 × 24 in · 8 ft²/unit
Units needed
×231
min ×176
→ 0.50 s 24 × 48 in (representative) · 8 ft²/unit
Units needed
×234
min ×179
→ 0.50 s 8 ft²/unit
USG Ceiling Tile
Units needed
×247
min ×189
→ 0.50 s 24 × 48 in · 8 ft²/unit
Units needed
×247
min ×189
→ 0.50 s 24 × 48 in · 8 ft²/unit
MergeWorks Ceiling Cloud
EchoDeco Cloud NRC 0.85 Unverified
Units needed
×339
min ×259
→ 0.50 s ~40 in triangle (representative) · 5 ft²/unit
Units needed
×377
min ×288
→ 0.50 s 11.8 × 47.25 in (representative) · 4 ft²/unit
Units needed
×385
min ×294
→ 0.50 s linear metal baffle · 4 ft²/unit
Units needed
×385
min ×294
→ 0.50 s 24 × 48 in · 8 ft²/unit
Units needed
×385
min ×294
→ 0.50 s 24 × 48 in · 8 ft²/unit
USG Ceiling Tile
Units needed
×433
min ×330
→ 0.50 s 24 × 24 in · 4 ft²/unit
Turf Design Wall Panel
Units needed
×1397
min ×1067
→ 0.50 s hex tile · 1 ft²/unit

Unverified — Not yet confirmed against a manufacturer datasheet — treat this figure with caution.

NRC > 1.0 — NRC above 1.00 is expected for thick or suspended products — under ASTM C423, edge diffraction lets a finite sample absorb more sound than its flat face area implies.